1. Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 2002 51:1351. -6. discussion 6-7.
2. Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001 26:2467-71.
3. Du JY, Aichmair A, Kueper J, et al. Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 2015 22:151-61.
4. Melcher RP, Puttlitz CM, Kleinstueck FS, et al. Biomechanical testing of posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976) 2002 27:2435-40.
5. Hott JS, Lynch JJ, Chamberlain RH, et al. Biomechanical comparison of C1-2 posterior fixation techniques. J Neurosurg Spine 2005 2:175-81.
6. Lapsiwala SB, Anderson PA, Oza A, et al. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 2006 58:516. -21. discussion 516-21.
7. Hong X, Dong Y, Yunbing C, et al. Posterior screw placement on the lateral mass of atlas: an anatomic study. Spine (Phila Pa 1976) 2004 29:500-3.
9. Lehman RA, Sasso RC. Current concepts in posterior C1-C2 fixation. Semin Spine Surg 2007 19:244-9.
10. Pan J, Li L, Qian L, et al. C1 lateral mass screw insertion with protection of C1-C2 venous sinus: technical note and review of the literature. Spine (Phila Pa 1976) 2010 35:E1133-6.
11. Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila pa 1976) 1990 15:11-4.
12. Tessitore E, Bartoli A, Schaller K, et al. Accuracy of freehand fluoroscopy-guided placement of C1 lateral mass and C2 isthmic screws in atlanto-axial instability. Acta Neurochir (Wien) 2011 153:1417-25.
13. Ma XY, Yin QS, Wu ZH, et al. C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine (Phila Pa 1976) 2009 34:371-7.
14. Currier BL, Maus TP, Eck JC, et al. Relationship of the internal carotid artery to the anterior aspect of the C1 vertebra: implications for C1-C2 transarticular and C1 lateral mass fixation. Spine (Phila Pa 1976) 2008 33:635-9.
15. Eck JC, Walker MP, Currier BL, et al. Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation. J Spinal Disord Tech 2007 20:505-8.
16. Hong JT, Lee SW, Son BC, et al. Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report. J Neurosurg Spine 2006 5:83-5.
17. Sai Kiran NA, Sivaraju L, Vidyasagar K, et al. Safety and accuracy of anatomic and lateral fluoroscopic-guided placement of C2 pars/pedicle screws and C1 lateral mass screws, and freehand placement of C2 laminar Screws. World Neurosurg 2018 118:e304-15.
18. Tan M, Wang H, Wang Y, et al. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine (Phila Pa 1976) 2003 28:888-95.
20. Rocha R, Safavi-Abbasi S, Reis C, et al. Working area, safety zones, and angles of approach for posterior C1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation. J Neurosurg Spine 2007 6:247-54.
21. Yi HJ, Hong JT, Lee JB, et al. Analysis of risk factors for posterior C1 screw-related complication: a retrospective study of 358 posterior C1 screws. Oper Neurosurg (Hagerstown) 2019 17:509-17.
22. Christensen DM, Eastlack RK, Lynch JJ, et al. C1 anatomy and dimensions relative to lateral mass screw placement. Spine (Phila Pa 1976) 2007 32:844-8.
23. Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery 2002 50:426-8.
25. Blagg SE, Don AS, Robertson PA. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement. J Spinal Disord Tech 2009 22:233-9.
26. Yeom JS, Buchowski JM, Park KW, et al. Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement. Spine J 2009 9:574-9.
28. Seybold EA, Baker JA, Criscitiello AA, et al. Characteristics of unicortical and bicortical lateral mass screws in the cervical spine. Spine (Phila Pa 1976) 1999 24:2397-403.
29. Su BW, Theologis AA, Byers RH, et al. Quantitative assessment of the anatomical footprint of the C1 pedicle relative to the lateral mass: a guide for C1 lateral mass fixation. Global Spine J 2018 8:507-11.
30. Chapman JR, Harrington RM, Lee KM, et al. Factors affecting the pullout strength of cancellous bone screws. J Biomech Eng 1996 118:391-8.